/*=============================================================================== Copyright 2020 Siemens Digital Industries Software ================================================== Copyright $2010. Siemens Product Lifecycle Management Software Inc. All Rights Reserved. ================================================== Copyright 2020 Siemens Digital Industries Software */ /** @file This file contains the error codes for the MESBVRINTEG module */ /* */ #ifndef MESBVRINTEG_ERRORS_H #define MESBVRINTEG_ERRORS_H #include #include /** @defgroup MESBVRINTEG_ERRORS MESBVRINTEG Errors @ingroup MESINTEG @{ */ /** An internal error has occurred. Please contact your system administrator. */ #define MESBVRINTEG_internal_error (EMH_MESBVRINTEG_error_base + 1) /** The target object is not of type Process nor Operation.*/ #define MESBVRINTEG_incorrect_selection_type (EMH_MESBVRINTEG_error_base + 10) /** An error has occurred while validating the selected data "%1$". */ #define MESBVRINTEG_exception_validating_data (EMH_MESBVRINTEG_error_base + 11) /** The release status of the object "%1$" is not part of the configured release statuses. */ #define MESBVRINTEG_no_release_status (EMH_MESBVRINTEG_error_base + 12) /** The release status flag "%1$" cannot be found. Please contact your system administrator. */ #define MESBVRINTEG_missing_release_flag (EMH_MESBVRINTEG_error_base + 13) /** The object type "%1$" cannot be found. Please contact your system administrator. */ #define MESBVRINTEG_incorrect_object_type (EMH_MESBVRINTEG_error_base + 14) /** The preference "%1$" is not in the specified format. */ #define MESBVRINTEG_incorrect_preference_specification (EMH_MESBVRINTEG_error_base + 15) /** No Work Area is assigned for the object "%1$". Please assign a Work Area to the object. */ #define MESBVRINTEG_no_work_area_assigned (EMH_MESBVRINTEG_error_base + 16) /** The structure of the object "%1$" is incorrect: it contains multi-level of processes. */ #define MESBVRINTEG_hierarchy_error_more_than_two_levels (EMH_MESBVRINTEG_error_base + 17) /** The structure of the object "%1$" is incorrect: it must contain at least one child Compound Operation or Operation child. */ #define MESBVRINTEG_hierarchy_error_no_comp_op_nor_op_children (EMH_MESBVRINTEG_error_base + 18) /** The structure of the object "%1$" is incorrect: it contains a mix of processes, compound operations and operations. */ #define MESBVRINTEG_hierarchy_error_mixed_comp_op_and_op (EMH_MESBVRINTEG_error_base + 19) /** A full export must be run before releasing an update. Perform a full export on the selected Execution Plan. */ #define MESBVRINTEG_full_export_creation_error (EMH_MESBVRINTEG_error_base + 20) /** The object class "%1$" cannot be found. Please contact your system administrator. */ #define MESBVRINTEG_workarea_preference_type_invalid (EMH_MESBVRINTEG_error_base + 21) /** The object class "%1$" is neither of type Process, nor Compound Operation, nor Operation, nor Step nor derived from any of these. Please contact your system administrator. */ #define MESBVRINTEG_workarea_preference_type_invalid_not_derived_from_proc_or_op (EMH_MESBVRINTEG_error_base + 22) /** Only a single Bill Of Processes (BOP) Window can be configured in the structure. Please remove any additional BOP Window from the execution Plan.*/ #define MESBVRINTEG_single_bop_window_validation_failed (EMH_MESBVRINTEG_error_base + 23) /** The EPM Task Template "%1$" does not exist. */ #define MESBVRINTEG_epmtask_template_absent (EMH_MESBVRINTEG_error_base + 24) /** More than one flow alternative path exist for the object "%1$". Please make sure there are no alternative flow paths for the object. */ #define MESBVRINTEG_flow_Alternative_paths (EMH_MESBVRINTEG_error_base + 25) /** The structure of the object "%1$" is incorrect: the root object of a Process Structure must not be of type Compound Operation, nor Operation, nor any of their derived types. */ #define MESBVRINTEG_hierarchy_invalid_root_object (EMH_MESBVRINTEG_error_base + 26) /** The dispatcher wait time limit, as specified in the preference "%1$", has been reached. Please check that the dispatcher services are running, and check the log file in the dispatcher staging directory for the request ID %2$ for more details. */ #define MESBVRINTEG_defined_time_limit_reached_for_dispatcher (EMH_MESBVRINTEG_error_base + 27) /** The dispatcher request "generatemeswirepfiles" could not be created. Please refer to the Teamcenter server log file for details. */ #define MESBVRINTEG_Failed_to_create_dispatcher_request (EMH_MESBVRINTEG_error_base + 28) /** The translation has failed for the request ID %1$. Please refer to the Teamcenter server log file for details. */ #define MESBVRINTEG_translation_failed (EMH_MESBVRINTEG_error_base + 29) /** The dispatcher is not installed. No MHT files will be generated for this request. Please contact your system administrator to intall and configure the "generatemeswirep" translator. */ #define MESBVRINTEG_dispatcher_not_installed (EMH_MESBVRINTEG_error_base + 30) /** The structure of the object "%1$" is incorrect: Compound Operations may only have Steps as children. */ #define MESBVRINTEG_hierarchy_invalid_comp_op (EMH_MESBVRINTEG_error_base + 31) /** The Work Area object "%1$" name is invalid. Work Area names must not include any whitespaces. */ #define MESBVRINTEG_work_area_name_invalid (EMH_MESBVRINTEG_error_base + 32) /** No full flow path was detected for the object "%1$". Please make sure there are no alternative flow paths for the object. */ #define MESBVRINTEG_flow_no_full_path (EMH_MESBVRINTEG_error_base + 33) /** The Application Object was absent from the previous Execution Plan, so the delta export cannot be executed. Please perform a full export on the selected Execution Plan again. */ #define MESBVRINTEG_ai_absent_in_execution_plan (EMH_MESBVRINTEG_error_base + 34) /** No Visualization Structure Context is attached to the previous Request Object. */ #define MESBVRINTEG_vsc_not_attached (EMH_MESBVRINTEG_error_base + 35) /** No release candidate can be found in the structure. */ #define MESBVRINTEG_no_release_candidate_present (EMH_MESBVRINTEG_error_base + 36) /** The Workflow Template is invalid. Please provide a valid Workflow template. */ #define MESBVRINTEG_invalid_workflow_template (EMH_MESBVRINTEG_error_base + 37) /** The root of the Bill Of Processes (BOP) Window must always be a Process. */ #define MESBVRINTEG_root_process_validation_failed (EMH_MESBVRINTEG_error_base + 38) /** Remove any additional Work Area from "%1$" because only one Work Area can be attached to an object. */ #define MESBVRINTEG_single_workarea_attached_validation_failed (EMH_MESBVRINTEG_error_base + 39) /** The object "%1$" has multiple effectivities. Only one effectivity is expected. */ #define MESBVRINTEG_multiple_effectivity (EMH_MESBVRINTEG_error_base + 40) /** The provided release status "%1$" cannot be applied to the object "%2$", because it already has the "%3$" status. */ #define MESBVRINTEG_invalid_release_status (EMH_MESBVRINTEG_error_base + 41) /** An execution plan must contain a process structure in order to be released to the Manufacturing Execution System (MES) application. */ #define MESBVRINTEG_execution_plan_missing_process_structure (EMH_MESBVRINTEG_error_base + 42) /** The release status "%2$" of the Change object "%1$" is not part of the Manufacturing Execution System (MES) release statuses. */ #define MESBVRINTEG_mcn_release_status_incorrect (EMH_MESBVRINTEG_error_base + 43) /** No configured release status is attached to the Change Object "%1$". */ #define MESBVRINTEG_mcn_no_release_status (EMH_MESBVRINTEG_error_base + 44) /** No effectivity is attached to the Change Object "%1$". */ #define MESBVRINTEG_mcn_no_effectivity (EMH_MESBVRINTEG_error_base + 45) /** The effectivity of the Change Object "%1$" differs from that of the referenced Plant Bill Of Processes (BOP) Window. */ #define MESBVRINTEG_mcn_effectivity_differ_from_window (EMH_MESBVRINTEG_error_base + 46) /** The Item Revision "%2$" attached to the Change Object "%1$" is not configured in the referenced Plant Bill Of Process (BOP) structure. Please attach the appropriate Item Revision to the Change Object. */ #define MESBVRINTEG_mcn_attached_input_line_not_configured (EMH_MESBVRINTEG_error_base + 47) /** No input line is attached to the Change Object "%1$". */ #define MESBVRINTEG_mcn_input_lines_absent (EMH_MESBVRINTEG_error_base + 48) /** Multiple release statuses are attached to the Change Object "%1$". Change Objects should have only one configured release status. */ #define MESBVRINTEG_mcn_multiple_release_status (EMH_MESBVRINTEG_error_base + 49) /** No value is provided for the Previous Effectivity property of the Change Object "%1$". */ #define MESBVRINTEG_mcn_previous_effectivity_absent (EMH_MESBVRINTEG_error_base + 50) /** The Change Object "%1$" is currently not effective for the "%2$" status. */ #define MESBVRINTEG_mcn_release_status_not_effectivity (EMH_MESBVRINTEG_error_base + 51) /** The previous effectivity of the Change Object "%1$" does not match the one of the impacted item "%2$". */ #define MESBVRINTEG_mcn_previous_effectivity_not_matching (EMH_MESBVRINTEG_error_base + 52) /** The release status of the Item "%2$" does not match the release status of the Change Object "%1$".*/ #define MESBVRINTEG_mcn_mismatch_release_status (EMH_MESBVRINTEG_error_base + 53) /** The standard text bulk update operation cannot continue, because of an invalid Change Notice revision with Item ID "%1$".*/ #define STX_bulk_update_invalid_item_id (EMH_MESBVRINTEG_error_base + 54) /** The standard text bulk update operation cannot continue, because of an invalid Revision Rule named "%1$".*/ #define STX_bulk_update_invalid_rev_rule_name (EMH_MESBVRINTEG_error_base + 55) /** The standard text bulk update operation cannot continue, because it is unable to create file "%1$".*/ #define STX_bulk_update_cannot_create_logfile (EMH_MESBVRINTEG_error_base + 56) /** The standard text bulk update operation cannot continue, because Microsoft Word is required yet not installed.*/ #define STX_bulk_update_cannot_find_word_installed (EMH_MESBVRINTEG_error_base + 57) /** The standard text bulk update encounted a problem. Please refer to the log dataset attached to the reference folder of the Change Notice for additional information*/ #define STX_bulk_update_problem_refer_log_dataset (EMH_MESBVRINTEG_error_base + 58) /** The standard text bulk update operation cannot continue, because the standard text Revision Rule does not configure a revision found in the Change Notice revision. Please refer to the log dataset attached to the reference folder of the change notice revision for additional information. */ #define STX_bulk_update_no_configured_revision (EMH_MESBVRINTEG_error_base + 59) /** The validation of the Process Structure has failed, because the property "Sign-off Required" is not set to "true" for the object "%1$".*/ #define MESBVRINTEG_signoff_signature_required (EMH_MESBVRINTEG_error_base + 60) /** The validation of the Work Area assigned to "%1$" has failed. Please associate the Manufacturing Execution System (MES) resource location to the Work Area.*/ #define MESBVRINTEG_workarea_resource_required (EMH_MESBVRINTEG_error_base + 61) /** The specified structure context type "%1$" is invalid.*/ #define MESBVRINTEG_invalid_structure_context_type (EMH_MESBVRINTEG_error_base + 62) /** The specified Collaboration Context object "%1$" is invalid because it must be of type "%2$".*/ #define MESBVRINTEG_invalid_execution_plan_type (EMH_MESBVRINTEG_error_base + 63) /** The execution plan "%1$" is not configured as work order.*/ #define MESBVRINTEG_no_work_order_configuration (EMH_MESBVRINTEG_error_base + 64) /** Find word order status operation has failed.*/ #define MESBVRINTEG_find_work_order_status_failed (EMH_MESBVRINTEG_error_base + 65) /** @} */ #include #endif