/* Copyright 2020 Siemens Digital Industries Software ================================================== Copyright 2010. Siemens Product Lifecycle Management Software Inc. All Rights Reserved. ================================================== Copyright 2020 Siemens Digital Industries Software */ #ifndef SYSTEMSENGINEERING_ERRORS_H #define SYSTEMSENGINEERING_ERRORS_H #include /** @defgroup SYSTEMSENGINEERING_ERRORS Errors @ingroup SYSTEMSENGINEERING @{ */ #define SYSTEMSENGINEERING_error_base EMH_SYSTEMSENGINEERING_error_base /** @name BUDGET_ERRORS_GROUP Budget related errors @{ */ /** BudgetDefinition Name error messages */ #define SYSTEMSENGINEERING_budget_definition_name_exist (SYSTEMSENGINEERING_error_base + 1) /** EditBudget operation-context line error */ #define SYSTEMSENGINEERING_edit_budget_context_line (SYSTEMSENGINEERING_error_base + 2) /** EditBudget operation error */ #define SYSTEMSENGINEERING_edit_budget_error (SYSTEMSENGINEERING_error_base + 3) /** This error implies an action cannot be performed as a stub is found */ #define SYSTEMSENGINEERING_stub_found (SYSTEMSENGINEERING_error_base + 4) /** @} */ /** @name SYSTEM_ENGINEERING_ERRORS_GROUP System Engineering related errors @{ */ /** The Top Line can not be deleted */ #define SYSTEMSENGINEERING_top_line (SYSTEMSENGINEERING_error_base + 51) /** Multiple revisions found for the Function */ #define SYSTEMSENGINEERING_multiple_function_revisions (SYSTEMSENGINEERING_error_base + 52) /** The object is released */ #define SYSTEMSENGINEERING_object_is_released (SYSTEMSENGINEERING_error_base + 53) /** The Function is referenced in other structure */ #define SYSTEMSENGINEERING_function_referenced (SYSTEMSENGINEERING_error_base + 54) /** The element "%1$" of type "%2$" (%3$) has already been added to the interface specification "%4$". */ #define SYSTEMSENGINEERING_element_already_exists (SYSTEMSENGINEERING_error_base + 55) /** @} */ /** @name Interface Management errors (Interface Specification, Interface Element, Signal Elements, etc). @{ */ /** The default value %1$ is not in the range of values defined for the property "%2$" (seg0DefaultValue) on "%3$". */ #define SYSTEMSENGINEERING_default_value_out_of_range (SYSTEMSENGINEERING_error_base + 101) /** The minimum value cannot be greater than the maximum value. */ #define SYSTEMSENGINEERING_min_value_greater_than_max (SYSTEMSENGINEERING_error_base + 102) /** The interaction can connect only one source and one target block. */ #define SYSTEMSENGINEERING_invalid_number_of_source_and_target_blocks (SYSTEMSENGINEERING_error_base + 103) /** The Direction of the Port %1$ was not changed because it is defined by the attached interface elements. */ #define SYSTEMSENGINEERING_failed_to_edit_port_direction (SYSTEMSENGINEERING_error_base + 104) /** The interface element "%1$" of type "%3$" with the subject "%2$" is already present on port "%4$" of "%5$". */ #define SYSTEMSENGINEERING_interface_element_already_exists (SYSTEMSENGINEERING_error_base + 105) /** The Exchange element subject "%1$" cannot be changed to "%2$", because an interface element with a same name, subject and type is already present on the selected port. */ #define SYSTEMSENGINEERING_subject_cannot_be_changed (SYSTEMSENGINEERING_error_base + 106) /** @} */ /** @} */ #endif