You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
145 lines
6.1 KiB
145 lines
6.1 KiB
/*
|
|
Copyright 2020 Siemens Digital Industries Software
|
|
==================================================
|
|
Copyright 2016.
|
|
Siemens Product Lifecycle Management Software Inc.
|
|
All Rights Reserved.
|
|
==================================================
|
|
Copyright 2020 Siemens Digital Industries Software
|
|
*/
|
|
|
|
/**
|
|
@file
|
|
|
|
Advanced PLM Services Configured Search Error Codes Declaration
|
|
*/
|
|
|
|
#ifndef SRH0APSCONFIGUREDSEARCH_ERRORS_H
|
|
#define SRH0APSCONFIGUREDSEARCH_ERRORS_H
|
|
|
|
#include <common/emh_const.h>
|
|
|
|
/**
|
|
@defgroup SRH0APSCONFIGUREDSEARCH_ERRORS Advanced PLM Services Configured Search Errors
|
|
@ingroup SRH0APSCONFIGUREDSEARCH
|
|
@{
|
|
*/
|
|
|
|
#define EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE EMH_SRH0APSCONFIGUREDSEARCH_error_base
|
|
|
|
/**
|
|
* An internal error has occurred in the Advanced PLM Services Configured Search (srh0apsconfiguredsearch) module: %1$. Please report this error to your system administrator.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_internal_error ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 1 )
|
|
|
|
/**
|
|
* The requested functionality "%1$" is not yet implemented.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_functionality_not_implemented ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 2 )
|
|
|
|
/**
|
|
* The definition of the search result column at index %1$ is invalid for search definitions of type "%2$".
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_invalid_search_result_column ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 3 )
|
|
|
|
/**
|
|
* The sort attribute "%1$" for search results is not formatted properly. It should be formatted as follows: "className.attributeName" or "className.attributeName.columnIndex".
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_improper_format_for_sort_attribute ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 4 )
|
|
|
|
/**
|
|
* The provided search criterion "%1$" is invalid. Please report this error to your system administrator.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_invalid_search_criterion ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 5 )
|
|
|
|
/**
|
|
* The provided search criterion "%1$" of type "%2$" is not used in the root search definition "%3$". Please report this error to your system administrator.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_unused_search_criterion ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 6 )
|
|
|
|
/**
|
|
* The provided root search criterion "%1$" is empty. Please report this error to your system administrator.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_empty_root_search_criterion ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 7 )
|
|
|
|
/**
|
|
* The provided search criterion "%1$" is empty. Please report this error to your system administrator.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_empty_search_criterion ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 8 )
|
|
|
|
/**
|
|
* No constructor is defined for the provided search criterion "%1$". Please report this error to your system administrator.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_constructor_not_found ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 9 )
|
|
|
|
/**
|
|
* The provided table layout is invalid, because the number of datatypes and "%1$" is different for the Search criterion "%2$". Please report this error to your system administrator.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_invalid_table_layout ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 10 )
|
|
|
|
/**
|
|
* The search argument "%1$" is mandatory and is not found in the input. Please report this error to your system administrator.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_missing_search_argument ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 11 )
|
|
|
|
/**
|
|
* The object "%1$" of type "%2$" does not have a searchable behavior.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_object_is_not_searchable ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 12 )
|
|
|
|
/**
|
|
* Saved Query has an invalid class.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_invalid_saved_query_in_search ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 13 )
|
|
|
|
/**
|
|
* The revision rule "%1$" does not have any valid clause
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_no_valid_clause_in_revision_rule ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 14 )
|
|
|
|
/**
|
|
* The revision rule "%1$" contains an invalid clause "%2$"
|
|
* for configuring major revisions in Model Context.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_invalid_revision_rule_clause ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 15 )
|
|
|
|
/**
|
|
* The Search type "%1$" cannot be found.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_invalid_search_type ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 16 )
|
|
|
|
/**
|
|
* The configuration filter cannot be applied on the column "%1$", because it is not of type "tag".
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_column_type_not_supported ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 17 )
|
|
|
|
/**
|
|
* The input data for the column "%1$" does not match the column type.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_column_type_mismatch ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 18 )
|
|
|
|
/**
|
|
* No input data are received for the column "%1$".
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_insufficient_column_data ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 19 )
|
|
|
|
/**
|
|
* The temporary table cannot be created because of a mismatch in the number of columns and their types.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_columnNameType_mismatch ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 20 )
|
|
|
|
/**
|
|
* The provided Configuration Context is not valid.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_no_config_context_provided ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 21 )
|
|
|
|
/**
|
|
* The provided tag is null.
|
|
*/
|
|
#define SRH0APSCONFIGUREDSEARCH_null_tag ( EMH_SRH0APSCONFIGUREDSEARCH_ERROR_BASE + 22 )
|
|
/**
|
|
@}
|
|
*/
|
|
|
|
#endif
|